Conducting all types of on-site surveys to identify the seismic resistance of industrial and administrative buildings located on the territory of the factory (29 bunker, reinforced concrete, prefabricated type buildings) and conducting analyzes using non-linear methods. Developing reinforcement designs for necessary structures.
Cement and clinker silos, preheating tower, packing plant buildings, mill buildings, rotary kiln and cooling tower building, storage rooms, laboratory.
YEAR OF CONSTRUCTION
2020-2021
CUSTOMER
Sanko Holding – POLİGON İnşaat A.Ş.
LOCATION
ADIYAMAN